{"id":4727,"date":"2024-01-28T08:48:54","date_gmt":"2024-01-28T08:48:54","guid":{"rendered":"https:\/\/samplehost.online\/?page_id=4727"},"modified":"2024-01-28T14:22:01","modified_gmt":"2024-01-28T14:22:01","slug":"level-profiler","status":"publish","type":"page","link":"https:\/\/stolwayanalytics.com\/index.php\/level-profiler\/","title":{"rendered":"Level Profiler"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"4727\" class=\"elementor elementor-4727\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a28b45c e-flex e-con-boxed e-con e-parent\" data-id=\"a28b45c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-ec19b58 e-con-full e-flex e-con e-child\" data-id=\"ec19b58\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-db92800 elementor-widget elementor-widget-heading\" data-id=\"db92800\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Level Profiler<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20db59f elementor-widget elementor-widget-text-editor\" data-id=\"20db59f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A &#8220;virtual window&#8221; into separators and vessels.<\/p><p>While DP and guided wave radar level transmitters \u2013 and even mechanical floaters and visual gauges \u2013 serve their purpose in light, sweet crudes and generally when water separates easily from oil, heavier and more viscous crude oils introduce much more complex layers and less defined levels in production separators.<\/p><p>With tight emulsions, long settling times and severe foaming, operators need better information to optimize separator throughput, and still avoid excess water on the oil outlet and liquid carry-over on the gas outlet.<\/p><p>The Stolway Level Profiler is the only technology on the market able to provide this level of detail and seamless representation of complex separator layers without any nuclear sources.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ebaa154 e-con-full e-flex e-con e-child\" data-id=\"ebaa154\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a7dd740 elementor-widget elementor-widget-image\" data-id=\"a7dd740\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/stolwayanalytics.com\/wp-content\/uploads\/2024\/01\/Untitled-design-96.png\" class=\"attachment-medium_large size-medium_large wp-image-4754\" alt=\"\" srcset=\"https:\/\/stolwayanalytics.com\/wp-content\/uploads\/2024\/01\/Untitled-design-96.png 500w, https:\/\/stolwayanalytics.com\/wp-content\/uploads\/2024\/01\/Untitled-design-96-300x300.png 300w, https:\/\/stolwayanalytics.com\/wp-content\/uploads\/2024\/01\/Untitled-design-96-150x150.png 150w\" sizes=\"(max-width: 500px) 100vw, 500px\" data-id=\"4754\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dc21445 e-flex e-con-boxed e-con e-parent\" data-id=\"dc21445\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ae436cc e-flex e-con-boxed e-con e-parent\" data-id=\"ae436cc\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5e2ed1e elementor-widget elementor-widget-n-accordion\" data-id=\"5e2ed1e\" data-element_type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9870\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-9870\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Features <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9870\" class=\"elementor-element elementor-element-18743c2 e-con-full e-flex e-con e-child\" data-id=\"18743c2\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-469689d elementor-widget elementor-widget-text-editor\" data-id=\"469689d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The Stolway Level Profiler employs a series of SeCaP sensors allowing operators to &#8220;see through the walls&#8221; of the separator:<\/p><ul><li>Accurate location of water, emulsion, oil, foam and free gas layers relative to top of weir plate<\/li><li>Seamless gradient color for varying water cut across emulsion layer<\/li><li>Customization of vertical resolution to customer requirements (1 cm resolution possible)<\/li><li>Optimization of resolution at critical levels in separator (e.g. just below top of weir plate)<\/li><li>Optional flushing capability for effective cleaning of sensors without affecting production<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9871\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-9871\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Technical Specification <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9871\" class=\"elementor-element elementor-element-d879172 e-con-full e-flex e-con e-child\" data-id=\"d879172\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9c2a432 elementor-widget elementor-widget-text-editor\" data-id=\"9c2a432\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><td colspan=\"2\" width=\"772\"><p><strong><b>MECHANICAL SPECIFICATIONS \u2013 PROFILER ROD <\/b><\/strong><\/p><\/td><\/tr><tr><td width=\"249\"><p>Rod diameter &amp; length<\/p><\/td><td width=\"523\"><p>80 mm OD (typ.), max. 30 m for one profiler rod (vertical)<\/p><\/td><\/tr><tr><td width=\"249\"><p>Rod material<\/p><\/td><td width=\"523\"><p>SS 316L, Duplex, Super Duplex, Inconel 625 or others upon request<\/p><\/td><\/tr><tr><td width=\"249\"><p>Construction<\/p><\/td><td width=\"523\"><p>Machined sections up to 3.5 m, bolted together in situ for longer rods<\/p><\/td><\/tr><tr><td width=\"249\"><p>Process connection<\/p><\/td><td width=\"523\"><p>Flanged, minimum 4&#8243; ANSI\/API, 150# &#8211; 900#, RF\/RTJ<\/p><\/td><\/tr><tr><td width=\"249\"><p>Number of sensors<\/p><\/td><td width=\"523\"><p>Selected by customer based on separator height and required resolution<\/p><\/td><\/tr><tr><td width=\"249\"><p>Design temperature<\/p><\/td><td width=\"523\"><p>125\u00b0C, 175\u00b0C, 225\u00b0C<\/p><\/td><\/tr><tr><td width=\"249\"><p>Design pressure<\/p><\/td><td width=\"523\"><p>Up to 450 bar (depending on process connection pressure rating)<\/p><\/td><\/tr><tr><td width=\"249\"><p>Enclosure protection<\/p><\/td><td width=\"523\"><p>IP66 (profiler rod terminals housing)<\/p><\/td><\/tr><tr><td width=\"249\"><p>Protective coating<\/p><\/td><td width=\"523\"><p>Not applicable<\/p><\/td><\/tr><tr><td colspan=\"2\" width=\"772\"><p><strong><b>MECHANICAL SPECIFICATIONS \u2013 CONTROLLER UNIT ENCLOSURE <\/b><\/strong><\/p><\/td><\/tr><tr><td width=\"249\"><p>Dimensions<\/p><\/td><td width=\"523\"><p>375 x 265 x 108 mm3 (14.8&#8243; x 10.4&#8243; x 4.3&#8243;)<\/p><\/td><\/tr><tr><td width=\"249\"><p>Material<\/p><\/td><td width=\"523\"><p>SS 316<\/p><\/td><\/tr><tr><td width=\"249\"><p>Mounting<\/p><\/td><td width=\"523\"><p>Stand-alone<\/p><\/td><\/tr><tr><td width=\"249\"><p>Enclosure protection<\/p><\/td><td width=\"523\"><p>IP66\/IP67<\/p><\/td><\/tr><tr><td width=\"249\"><p>Protective coating<\/p><\/td><td width=\"523\"><p>Not applicable<\/p><\/td><\/tr><tr><td colspan=\"2\" width=\"772\"><p><strong><b>ELECTRICAL SPECIFICATIONS <\/b><\/strong><\/p><\/td><\/tr><tr><td width=\"249\"><p>Hazardous Area classification<\/p><\/td><td width=\"523\"><p>Ex ia protection from Sensor Unit to Safe Area Analyzer Interface cabinet<\/p><p>Profiler Rod (Sensor Unit): ATEX\/IECEx II 1\/(1)G Ex ia\/[Ex ia] IIB T4-T2 Ga<\/p><p>Controller Unit enclosure: ATEX\/IECEx Ex ia IIB T4 Ga -40\u00b0C \u2264 Ta \u2264 +60\u00b0C<\/p><p>Analyzer Interface cabinet: Must be placed in Safe Area<\/p><p>IS barriers: Located in Safe Area within the Analyzer Interface cabinet. If required, they can be installed in Zone 2<\/p><\/td><\/tr><tr><td width=\"249\"><p>ATEX certificate<\/p><\/td><td width=\"523\"><p>Presafe 16 ATEX 8593X<\/p><\/td><\/tr><tr><td width=\"249\"><p>IECEx certificate<\/p><\/td><td width=\"523\"><p>PRE 14.0004X<\/p><\/td><\/tr><tr><td width=\"249\"><p>Ambient temperature<\/p><\/td><td width=\"523\"><p>-40\u00b0C \u2264 Ta \u2264 +60\u00b0C<\/p><\/td><\/tr><tr><td width=\"249\"><p>Outputs<\/p><\/td><td width=\"523\"><p>RS485 Modbus RTU, 4\u201320 mA (e.g., for oil\/water interface level &amp; alarm)<\/p><\/td><\/tr><tr><td width=\"249\"><p>External power supply<\/p><\/td><td width=\"523\"><p>120\/230VAC, 24VDC to Safe Area Analyzer Interface cabinet<\/p><\/td><\/tr><tr><td width=\"249\"><p>Power consumption<\/p><\/td><td width=\"523\"><p>&lt; 10 W<\/p><\/td><\/tr><tr><td width=\"249\"><p>Cable entry<\/p><\/td><td width=\"523\"><p>Profiler Rod terminals housing: Factory connected instrument cable<\/p><p>Controller Unit enclosure: Factory connected instrument cable + M20<\/p><\/td><\/tr><tr><td width=\"249\"><p>Maximum cable length<\/p><\/td><td width=\"523\"><p>Profiler Rod to Controller Unit: 5 m<\/p><p>Controller Unit to Safe Area barrier modules: 500 m<\/p><\/td><\/tr><tr><td colspan=\"2\" width=\"772\"><p><strong><b>PERFORMANCE SPECIFICATIONS <\/b><\/strong><\/p><\/td><\/tr><tr><td width=\"249\"><p>Primary measurement<\/p><\/td><td width=\"523\"><p>Water, emulsion, oil, foam &amp; gas profile (Modbus RTU serial output)<\/p><p>Water level (% or mm) (4\u201320 mA output)<\/p><\/td><\/tr><tr><td width=\"249\"><p>Measurement principle<\/p><\/td><td width=\"523\"><p>Single Electrode Capacitance (SeCaP)<\/p><\/td><\/tr><tr><td width=\"249\"><p>Measurement range<\/p><\/td><td width=\"523\"><p>Defined by profiler rod Active Measurement Section length<\/p><\/td><\/tr><tr><td width=\"249\"><p>Number of sensors<\/p><\/td><td width=\"523\"><p>Selected by customer based on separator height and required resolution<\/p><\/td><\/tr><tr><td width=\"249\"><p>Profile resolution<\/p><\/td><td width=\"523\"><p>Defined by Active Measurement Section length \/ Number of sensors<\/p><\/td><\/tr><tr><td width=\"249\"><p>Sensitivity<\/p><\/td><td width=\"523\"><p>Each sensor can distinguish between water, emulsion (incl. varying water content across emulsion layer), oil, foam and gas<\/p><\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-9872\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-9872\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Applications Fields <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9872\" class=\"elementor-element elementor-element-5691214 e-con-full e-flex e-con e-child\" data-id=\"5691214\" data-element_type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-9872\" class=\"elementor-element elementor-element-dab4394 e-flex e-con-boxed e-con e-child\" data-id=\"dab4394\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9c42e01 elementor-widget elementor-widget-text-editor\" data-id=\"9c42e01\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The Stolway Level Profiler employs a series of SeCaP sensors allowing operators to &#8220;see through the walls&#8221; of the separator:<\/p><ul><li>Accurate location of water, emulsion, oil, foam and free gas layers relative to top of weir plate<\/li><li>Seamless gradient color for varying water cut across emulsion layer<\/li><li>Customization of vertical resolution to customer requirements (1 cm resolution possible)<\/li><li>Optimization of resolution at critical levels in separator (e.g. just below top of weir plate)<\/li><li>Optional flushing capability for effective cleaning of sensors without affecting production<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Level Profiler A &#8220;virtual window&#8221; into separators and vessels. While DP and guided wave radar level transmitters \u2013 and even mechanical floaters and visual gauges \u2013 serve their purpose in light, sweet crudes and generally when water separates easily from oil, heavier and more viscous crude oils introduce much more complex layers and less defined &hellip; <a href=\"https:\/\/stolwayanalytics.com\/index.php\/level-profiler\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">Level Profiler<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4727","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/stolwayanalytics.com\/index.php\/wp-json\/wp\/v2\/pages\/4727","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stolwayanalytics.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/stolwayanalytics.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/stolwayanalytics.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/stolwayanalytics.com\/index.php\/wp-json\/wp\/v2\/comments?post=4727"}],"version-history":[{"count":19,"href":"https:\/\/stolwayanalytics.com\/index.php\/wp-json\/wp\/v2\/pages\/4727\/revisions"}],"predecessor-version":[{"id":4858,"href":"https:\/\/stolwayanalytics.com\/index.php\/wp-json\/wp\/v2\/pages\/4727\/revisions\/4858"}],"wp:attachment":[{"href":"https:\/\/stolwayanalytics.com\/index.php\/wp-json\/wp\/v2\/media?parent=4727"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}